HP (Hewlett-Packard) ML110 G6 User Manual

Page of 115
 
 
Diagnostics tools  95  
 
 
Clearing CMOS    
You may need to clear the Setup configuration values (CMOS) if the configuration has been 
corrupted, or if incorrect settings made in the Setup Utility caused error messages to be unreadable.  
Use switch 1 of the system configuration switch (PCHSW1) to clear the CMOS data. See 
page 103
 
for the location of this switch. 
To clear CMOS:  
1. 
Perform the pre-installation procedure. 
2. 
Locate the PCHSW1 switch on the system board. 
3. 
If necessary, remove any assemblies or cables that prevent access to the PCHSW1 switch. 
4. 
Flip switch 1 to the On position for about 3 seconds.  
5. 
Flip switch 1 back to the default Off position. 
6. 
Perform the post-installation procedure. 
7. 
During POST, press F10 to access the Setup Utility.  
8. 
Press F9 to load the system default values. 
9. 
Press F10 to save the changes you made and close the Setup Utility. 
Recovering BIOS   
An interruption during a BIOS update procedure (for example, a power outage) can corrupt the BIOS 
code, which will cause the system to go into an unbootable state. You need to access and execute the 
boot block code to reboot the server and recover the regular BIOS code. 
Use switch 2 of the system configuration switch (PCHSW1) to execute the boot block code. See 
page 103
 for the location of this switch. 
To execute the BIOS boot block code: 
1. 
 and download the following files to the root directory of a bootable device.  
You can use a diskette, an external USB drive, or a CD/DVD. 
a. 
ROMPAQ.exe 
b. 
CPQSRVR2.cpu 
c. 
CPQO270x.xxx 
d. 
CONFIG.sys 
2. 
Create and label a bootable ROMPAQ device using the downloaded files.  
3. 
Change the command line in CONFIG.sys with: 
shell = rompaq.exe /! /U CPQSRVR2.CPU CPQO260x.xxx
4. 
Perform the pre-installation procedure.