HP (Hewlett-Packard) ML110 G6 User Manual

Page of 115
 
 
Diagnostics tools  94  
 
 
Recording custom Setup values  
Keep a record of the custom Setup values you have set up for your system BIOS. If the custom values 
ever need restoring (after a CMOS clear, for example), you must run the Setup Utility and enter these 
custom settings again. Make sure to update this record whenever you make any change to these 
Setup settings or install new hardware. 
You can either record the Setup values manually (hard copy) or use a CMOS backup utility. 
To manually record the custom Setup values: 
1. 
Access the Setup utility. 
2. 
Go through each menu and submenus page, and press Print Screen to make a hard copy.  
3. 
For multiple page menus, move to each page and print each screen. 
If a printer is not available, write down the values on a piece of paper. Make sure to write them 
down legibly and accurately. 
4. 
Label and date the Setup values hard copy, and then store it in a safe and accessible place, 
preferably with other user documentation for your ProLiant server. 
CMOS backup utility  
There are third-party utilities that read the CMOS settings and record them to a regular file, which can 
then be backed up through normal means, or copied to an external storage media. Some of these 
utilities also offer the option of restoring the CMOS settings so you need not re-enter them manually. 
These utilities are not always compatible with all versions of CMOS or types of CMOS. In addition, 
these utilities are not compatible with all operating system versions. Be sure to use a CMOS backup 
utility that is designed for the particular CMOS type and OS version installed in your ProLiant server. 
For information on a compatible CMOS backup utility, contact your local HP representative.  
Loading system defaults  
If your system fails after you make changes in the Setup menus, reboot the server, enter Setup and 
load the system default settings to correct the error.  
To load the system defaults: 
1. 
Reboot the server in a normal manner.  
2. 
During POST, press F10 to access the Setup Utility.  
3. 
Press F9 to load the default values.  
4. 
Press F10 to save the changes you made and close the Setup Utility.