Schneider Electric 17S Series User Manual

Page of 146
8
Hazards, Warnings and Guidelines, continued
CAUTION!
SAFETY INTERLOCKS
Schneider recommends the installation of a safety interlock with separate contacts 
for each motor. Such a system should be hard wired with over–travel limit switches 
and a suitable emergency stop switch. Any interruption of this circuit or fault 
indication should:
l
Open the motor contacts
l
Shunt dynamic braking resistors across each motor, if they are present.
Failure to observe this precaution can result in equipment damage.
CAUTION!
ELECTROSTATIC COMPONENTS
The drives contain electrostatically sensitive components that may be damaged by 
improper handling. Appropriately discharge yourself before touching the drive and 
avoid contact with highly insulating materials (artificial fabrics, plastic film, and so 
on). Place the drive on a conductive surface.
Failure to observe this precaution can result in equipment damage.