Siemens LR 460 User Manual

Page of 123
7ML19985JM01
SITRANS LR 460 – INSTRUCTION MANUAL 
Page 23
mmmmm
Wi
ri
ng
Hazardous area installations 
Product Nameplate
Instructions specific to hazardous area installations
(Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
The following instructions apply to equipment covered by certificate number 
Sira 06 ATEX 9218X.
1.
For use and assembly, refer to the main instructions.
2.
The equipment is certified for use as Category II 1D, 1/2 D & 2D equipment. The 
Essential Health and Safety Requirements are assured by compliance with 
IEC 61241-0: 2004 and IEC 61241-1: 2004. 
3.
The equipment may be used with dust and fibers with apparatus temperature 
class T (see table below).
Note: 
The nameplate shown is a typical example. Please check the nameplate on your 
device for your specific device configuration.
Note: 
Installation shall be performed only by qualified personnel and in accordance 
with local governing regulations. 
Siemens Milltronics Process Instruments Inc., Peterborough
Made in Canada
SITRANS LR 460 Radar Level Meter
Serial #
Amb. Temp.:
Enclosure:
Output:
Power Rating:
TYPE/NEMA 4X, 6 / IP67
7ML5426-0AA00-0AC-0
IECEx SIR 06.0058X
Ex tD A20 IP67 T85°C
4 - 20 mA HART
– 40°C to 65°C
100 - 230 V
,
±15%, 50/60 Hz, 6 W
Do Not Open in an explosive dust atmosphere.
II 1D, 1/2 D, 2D
Ex tD A20 IP67 T85°C
SIRA 06ATEX9218X
Canada 267P-LR460
0518
0891
GYZ/S1034567