Manual Do Utilizadoríndice analíticoIntroduction14Installation15Unpacking15Installation15Panel-Mounting15Cleaning16Field Upgrade Options17Options Modules and Functions17Preparing to Install or Remove Options Modules18Removing/Replacing Option Modules19Replacing the Instrument in its Housing20Auto Detection of Option Modules20Replacement of Power Supply or Input Boards20Data Recorder Board21Electrical Installation22Installation Considerations22AC Power Wiring - Neutral for 100 to 240V AC versions22Wire Isolation22Use of Shielded Cable23Noise Suppression at Source23Sensor Placement Thermocouple or RTD24Thermocouple Wire Identification Chart24Connections and Wiring25Power Connections26Power Connections - Mains Powered Instruments26Power Connections - 24/48V AC/DC Powered Instruments27Universal Input Connections27Universal Input Connections - Thermocouple T/C27Universal Input Connections – PT100 / NI120 RTD input28Universal Input Connections - Linear Volt, mV or mA input28Option Slot 1 Connections29Option Slot 1 – Single Relay Output Module29Option Slot 1 – Single SSR Driver Output Module29Option Slot 1 - Triac Output Module29Option Slot 1 - Linear Voltage or mADC Output module30Option Slot 2 Connections30Option Slot 2 – Single Relay Output Module30Option Slot 2 - Dual Relay Output Module30Option Slot 2 – Single SSR Driver Output Module31Option Slot 2 – Dual SSR Driver Output Module31Option Slot 2 - Triac Output Module31Option Slot 2 - Linear Voltage or mADC Output module32Option Slot 2 - Transmitter Power Supply Module32Option Slot 3 Connections32Option Slot 3 – Single Relay Output Module32Option Slot 3 - Dual Relay Output Module33Option Slot 3 – Single SSR Driver Output Module33Option Slot 3 – Dual SSR Driver Output Module34Option Slot 3 - Triac Output Module34Option Slot 3 - Linear Voltage or mADC Output module34Option Slot 3 - Transmitter Power Supply Module35Option Slot A Connections35Option Slot A Connections – Basic Auxiliary Input Module35Option Slot A Connections - Digital Input A Module35Option Slot A Connections - Ethernet Communications Module35Option Slot A Connections - RS485 Serial Communications Module36Option Slot B Connections36Option Slot B Connections – Digital Input B Full Auxiliary Module36Option Slot B Connections – Full Auxiliary Input B Module36Powering Up37Powering Up Procedure37Front Panel Overview37Display37LED Functions38Keypad38Messages and Error Indications39Start-up Errors39Configuration Problem39Input Problems39Un-Calibrated Input Detection39PV Over-range or Under-range Indication40Auxiliary Input Over-range or Under-range Indication40USB Data Transfer Problems40Getting Help40Second Level Support40Third Level Support40Configuration and Use41Operation Mode41Base, Trend & Profile Operating Screens41Navigating in Operator Mode43Adjusting the Local Setpoints43Adjusting the Setpoint Ramp Rate44Selecting Automatic or Manual Mode44Control Enable or Disable44Main Menu45Entry into the Main Menu45Navigating the Main Menu45Unlock Codes45Setup Wizard46Manual entry to the Setup Wizard46Navigating in the Setup Wizard46Supervisor Mode47Entry into Supervisor Mode47Navigating in Supervisor Mode47Configuration Menu48Entry into the Configuration Menu48Navigating the Configuration Menu48Input Configuration Sub-Menu49Control Configuration Sub-Menu50Output Configuration Sub-Menu52Alarm Configuration Sub-Menu53Communications Configuration Sub-Menu53Recorder Configuration Sub-Menu54Clock Configuration Sub-Menu55Display Configuration Sub-Menu55Lock Code View56Navigating Lock Code View56Lost Lock Codes56Forcing Lock Code View56Resetting To Defaults57Automatic Tuning Menu57Profiler Setup Menu58Profiler Control Menu61USB Menu62Recorder Menu63Product Information Mode63Service Information Mode64The USB Interface65Using the USB Port65USB Memory Stick Folders & Files65The Data Recorder Option66Introduction66Changes To Operation Mode66Memory Use Bar Graph66The Profiler67Profile Components67Profile Starting & Standard Segments68Loops Segments69Profile Running / Holding vs. Hold Segments69The Auto-Hold Feature70Profile Cycles & Repeat Sequences71Power/Signal Lost Recovery Actions71Profile End Actions72Profile Abort Actions73Manually Tuning Controllers74Single Control Tuning PID with Primary Output only74Dual Control Tuning PID with Primary and Secondary Outputs75PI Tuning Valve, Damper & Speed Controllers75Fine Tuning.77Serial Communications78Supported Protocols78RS485 Configuration78Ethernet Configuration78Supported Modbus Functions80Function Descriptions80Function 06 - Write Single Register81Function 08 - Loopback Diagnostic Test81Function 16 - Write Multiple Registers 0x10 Hex81Function 23 Hex - Read / Write Multiple Registers 0x17 hex82Exception Responses82Modbus Parameters83Universal Process Input Parameters84Option Slot A Parameters86Option Slot B Parameters87Option Slot 1 Parameters88Option Slot 2 Parameters90Option Slot 3 Parameters93Option Slot 4 Parameters96Setpoint Parameters101Control Parameters102Alarm parameters104Recorder & Clock Parameters106Display Parameters109Profiler Control & Status Parameters112Profile Setup Via Modbus114Instruction Sequence to create a profile at a specified profile position115Instruction Sequence to edit an existing Profile Header115Instruction Sequence to read a profile115Creating Or Editing A Profile Header116Creating, Editing or Inserting Segments117Segment Data119Deleting Profiles119Delete A Segment120Get Segments Remaining121Edit Response Message From Instrument121Command Response Data122Read A Profile Header122Read A Segment124Segment Data126Read Profile Name126Read Profile Memory Status128Read Profile Status128Instrument Data129Calibration130Calibration Reminder130Equipment Required For Checking or Calibrating The Universal Input130Calibration Check130Recalibration Procedure131Appendix 1 – Glossary of Terms Used132PC SOFTWARE165Using The Software165Instrument Configuration166Configuring Supervisor Mode166Configuring Enhanced Operator Mode166Profile Creation And Editing167Changing the Start-up Splash Screen169Changing the Alternate Display Language169Instrument Simulation169Configuring The Connection169Network Configuration For Modbus TCP Options171Instrument Details171Edit Modbus Settings172Fixing An IP Address172Appendix 2 - Specifications173Universal Process Input173General Input Specifications173Thermocouple Input173Thermocouple Types & Ranges173Thermocouple Performance174Resistance Temperature Detector RTD Input174RTD Types & Ranges174RTD Performance174DC Linear Input175DC Linear Types & Ranges175DC Linear Performance175Auxiliary Inputs175Auxiliary Input Performance175Digital Inputs176Digital Input Performance176Output Specifications177Single Relay Output Performance177Dual Relay Output Performance177Quad Relay Output Performance177Single Dual SSR Driver Output Performance177Dual SSR Driver Output Performance177Triac Output Performance178DC Linear Output Types & Ranges178DC Linear Output Performance17824V Transmitter Power Supply Performance178Communications179PC Configuration Socket179RS485179Ethernet179USB Socket179Display180Control Loop180Data Recorder Option180Profiler Option181Alarms181Conditions For Use182Operating Conditions182Standards182Dimensions182Appendix 3 - Product Coding183Tamanho: 3 MBPáginas: 184Language: EnglishAbrir o manual