User ManualTable of ContentsNFPA Standards4NFPA Standards4Underwriters Laboratories Documents4Other41. Product Description7Overview7Features7Options7Circuits8Input Circuits8Output circuits8Front Panel Control Switches8Suplemental Documentation8Control Panel9DIP Switch Functions10Options10Transmitter Module - 4XTM10Zone Relay Module - 4XZM10Remote Annunciator - RZA-4X11LED Interface Module - 4XLM11Specifications12AC Power12Battery (lead acid only)12Initiating Device Circuits12Notification Appliance and Releasing Circuits12Alarm and Trouble Relays12Resettable Power12Nonresettable Power12RMS Regulated Power122. Installation13Cabinet Mounting13Removal of Circuit Board13Mounting of Cabinet13Attaching Conduit13Reinstallation of Circuit Board14Installing Optional Voltmeter/Ammeter15Power Connections16AC Connections16Battery (DC) Connections16Power-limited Wiring Requirements17Initiating Device Circuits18Four-Wire Smoke Detector Connections19Output Circuits20Notification Appliance Circuits20Releasing Circuits21Alarm Relay Circuit22Trouble Relay Circuit22Powering External Devices22Optional Modules23Overview23Installation - Upper Position23Installation - Lower Position24Setup and Configuration25Transmitter Module - 4XTM25Zone Relay Module - 4XZM26LED Interface Module - 4XLM27Setting Mode of Operation28DIP Switch Functions28Switch #1 - Cross Zone28Switch #2 - Supervisory/Releasing Service29Switch #3 and #4 - Timer Delay29Switch # 5 and #6 - Abort Function29Zone Relay Module Configuration30Power-Up Procedure313. System Operation33System Status LEDs33Control Switches34Zone Status LEDs34Piezo35Supervisory Service35Zone Disable35Last Event Recall36Non-Silenceable Service36Sprinkler Supervisory Tracking36System Events36Standby Condition36System Trouble Condition36Single Zone in Alarm (Cross Zone) Condition37Both Zones in Alarm (Cross Zone) Condition37Manual Discharge Station Alarm Condition37Brownout Condition37Appendix A: Secondary Power Calculations39Standby Battery Requirements39Calculating the Battery Capacity40Appendix B: Compatible Devices41Two-wire Smoke Detectors, UL Listed41Four-wire Smoke Detectors, UL Listed42FM Approved Releasing Devices42Notification Appliances, UL Listed43Door Holders, UL Listed4524 VDC Relays, UL Listed45Appendix C: NFPA Standard-Specific Requirements47Minimum System Requirements47Additional Requirements47NFPA 72 - Signaling Systems for Central Station Service (Protected Premises Unit)47NFPA 72 - Auxiliary Fire Alarm System47NFPA 72 - Remote Station Fire Alarm System47Digital Alarm Communicator/Transmitter - Noti-Fire 911AC48Universal Digital Alarm Communicator - 411UDAC49Local Energy Municipal Box50Remote Station Receiver - RS82-951Appendix D: Testing & Maintenance53Testing53Inspection53Alarm Test53Maintenance53Troubleshooting53Size: 1.84 MBPages: 60Language: EnglishOpen manual