User Manual (BBS2400LP)Table of Contents1. Introduction1Section Outline1Server Board Use Disclaimer22. Server Board Overview3Figure 1. Intel® Server Board S2400LP (Base SKU)3Table 1. Intel® Server Board S2400LP Feature Set3Server Board Connector and Component Layout52.1.1 Board Rear Connector Placement5Figure 2. Intel® Server Board S2400LP Components5Server Board Mechanical Drawings6Figure 3. Rear Panel Connector Placement6Figure 4. Intel® Server Board S2400LP – Mounting Holes Locations6Figure 5. Intel® Server Boards S2400LP – Major Connector Pin-1 Locations73. Product Architecture Overview8High Level Product Features8Table 2. Intel® Server Board S2400LP Features8Processor Support9Figure 6. Intel® Server Boards S2400LP Functional Block Diagram9Processor Socket Assembly10Processor Population Rules10Figure 7. Processor Socket Assembly10Table 3. Mixed Processor Configurations11Processor Functions Overview13Intel®QuickPath Interconnect13Integrated Memory Controller (IMC) and Memory Subsystem14Figure 8. Processor with IMC Functional Block Diagram14Supported Memory15Table 4. UDIMM Support Guidelines15Table 5. RDIMM Support Guidelines16Table 6. LRDIMM Support Guidelines16Memory Population Rules17Figure 9. Intel® Server Board S2400LP DIMM Slot Layout17Publishing System Memory18RAS Features18Processor Integrated I/O Module (IIO)19Riser Card Support20Table 7. CPU1 and CPU2 PCIe Connectivity20Riser Types21Network Interface21Figure 10. PCIe Riser for Slot 121Figure 11. PCIe Riser for Slot 221I/O Module Support22Intel® C600-A/B PCH Functional Overview22Figure 12. Intel® C600-A/B PCH connection22Table 8. External RJ45 NIC Port LED Definition22PCI Express*23Universal Serial Bus (USB)23Serial Attached SCSI(SAS) and Serial ATA(SATA) Controller23Table 9. Intel® Server Board S2400LP SATA/SAS port24Table 10. Intel® RAID C600 Storage Upgrade Key Options for S2400LP24PCI Interface25Low Pin Count (LPC) Interface25Digital Media Interface (DMI)25Serials Peripheral Interface (SPI)25Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)25Advanced Programmable Interrupt Controller (APIC)25Real Time Clock (RTC)26GPIO26Enhanced Power Management26Fan Speed Control26Intel®Virtualization Technology for Direct I/O (Intel®VT-d)26KVM/Serial Over LAN (SOL) Function26IDE-R Function27Manageability27System Management Bus (SMBus* 2.0)27Network Interface Controller (NIC)283.4.19.1 MAC Address Definition (TBD)28Figure 13. 1GbE NIC port LED28Table 11. NIC Status LED283.4.19.2 LAN Manageability293.4.19.3 Wake-On-LAN293.4.19.4 LAN Connector Ordering293.4.19.5 Intel®I350 Thermal Sensor29InfiniBand* Controller29Figure 14. ConnectX®-3 function block diagram29Device Interfaces30Quad Small Form-factor Pluggable (QSFP) connector30Table 12. Network Port Configuration30Baseboard Management Controller Overview31Figure 15. Connection between ConnectX®-3 and QSFP31Figure 16. Integrated BMC implementation overview31Figure 17. BMC Functional Block Diagram32Super I/O Controller333.6.1.1 Keyboard and Mouse Support333.6.1.2 Wake-up Control33Graphics Controller and Video Support33Table 13. Video Modes333.6.3 Remote KVM34Table 14. Video mode344. Platform Management Functional Overview35Baseboard Management Controller (BMC) Firmware Feature Support35IPMI 2.0 Features35Non IPMI Features35New Manageability Features37Advanced Configuration and Power Interface (ACPI)38Platform Management SMBus* and I2C Implementation38Table 15. ACPI Power States38BMC Internal Timestamp Clock39Sensor Monitoring39Messaging Interfaces39Channel Management40User Model40Table 16. Standard Channel Assignments40Table 17. Default User Values40Sessions41Table 18. Channel/Media-specific minimum number of sessions41BMC LAN Channels424.6.4.1 Baseboard NICs424.6.4.2 Dedicated Management Channel424.6.4.3 Concurrent Server Management Use of Multiple Ethernet Controllers42IPV6 Support434.6.5.1 LAN Failover44System Event Log (SEL)44Servicing Events44SEL Entry Deletion44SEL Erasure45SEL Extension Capabilities45Sensor Data Record (SDR) Repository45Field Replaceable Unit (FRU) Inventory Device45Diagnostics and Beep Code Generation45Table 19. BMC Beep Codes45Diagnostics Interrupt (NMI)46BMC Basic and Advanced Management Features46Table 20. NMI Signal Generation and Event Logging46Table 21. Basic and Advanced Management Features46Enabling Advanced Manageability Features47Table 22. Management features and Benefits474.12.1.1 Keyboard, Video and Mouse (KVM) Redirection484.12.1.2 Remote Console484.12.1.3 Performance484.12.1.4 Security484.12.1.5 Availability484.12.1.6 Timeout494.12.1.7 Usage494.12.2 Media Redirection494.12.2.1 Availability504.12.2.2 Network Port Usage504.12.3 Embedded Web server504.12.4 Data Center management Interface (DCM)514.12.5 Local Directory Authentication Protocol (LDAP)514.12.6 Platform/Chassis Management524.12.7 Thermal Control524.12.7.1 Fan Speed Control524.12.7.2 System Configuration Using FRUSDR Utility534.12.8 Node Power On/Off Control53Intel® Intelligent Power Node Manager53Overview53Table 23. Fan Profile Mapping53Features54Management Engine (ME)54Overview54BMC – Management Engine (ME) Distributed Model54ME System Management Bus (SMBus*) Interface55Figure 18. Management Engine Distribution Model55BMC - Management Engine Interaction56ME Power and Firmware Startup56SmaRT/CLST56Other Platform Management57Wake On LAN (WOL)57PCI Express* Power management57PMBus*57Node Power policies57BIOS Password Protection57Trusted Platform Module(TPM) Support584.17.1 TPM Security BIOS594.17.2 Physical Presence594.17.3 TPM Security Setup Options604.17.4 Security Screen604. BIOS Setup Interface60HotKeys Supported During POST60Table 24. POST HotKeys Recognized60POST Logo/Diagnostic Screen61BIOS Boot Pop-up Menu61BIOS Setup Utility61BIOS Setup Operation62Setup Page Layout62Table 25. BIOS Setup Page Layout62Entering BIOS Setup63Setup Navigation Keyboard Commands63Table 26. BIOS Setup: Keyboard Command Bar63Setup Screen Menu Selection Bar64BIOS Setup Utility Screens655.4.2.1 Map of Screens and Functionality65Table 27. Screen Map655.4.2.2 Main Screen (Tab)67Figure 19. Main Screen67Table 28. Setup Utility – Main Screen Fields675.4.2.3 Advanced Screen (Tab)68Figure 20. Advanced Screen69Table 29. Setup Utility – Advanced Screen Display Fields695.4.2.4 Processor Configuration70Figure 21. Processor Configuration Screen70Table 30. Setup Utility — Processor Configuration Screen Fields715.4.2.5 Power and Performance Policy75Figure 22. Power and Performance Configuration Screen76Table 31. Setup Utility – Power and Performance Configuration Screen Fields76Table 32. Power/Performance Profiles765.4.2.6 Memory Configuration78Figure 23. Memory Configuration Screen78Table 33. Setup Utility – Memory Configuration Screen Fields795.4.2.7 Memory RAS and Performance Configuration80Figure 24. Memory RAS and Performance Configuration Screen805.4.2.8 Mass Storage Controller Configuration81Table 34. Setup Utility – Memory RAS and Performance Configuration Fields81Figure 25. Mass Storage Controller Configuration Screen82Table 35. Mass Storage Controller Configuration Fields825.4.2.9 PCI Configuration83Figure 26. PCI Configuration Screen83Table 36. Setup Utility – PCI Configuration Screen Fields845.4.2.10 NIC configuration85Figure 27. NIC Configuration Screen Field86Table36. Setup Utility - NIC Configuration Screen Field865.4.2.11 Serial Port Configuration925.4.2.12 USB Configuration92Figure 28. Serial Port Configuration Screen92Table 37. Setup Utility – Serial Ports Configuration Screen Fields92Figure 29. USB Configuration Screen93Table 38. Setup Utility – USB Controller Configuration Screen Fields935.4.2.13 System Acoustic and Performance Configuration94Figure 30. System Acoustic and Performance Configuration94Table 39. Setup Utility – System Acoustic and Performance Configuration Screen Fields955.4.2.14 Security Screen (Tab)97Figure 31. Security Screen97Table 40. Setup Utility – Security Configuration Screen Fields985.4.2.15 Server Management Screen (Tab)99Figure 32. Server Management Screen99Table 41. Setup Utility – Server Management Configuration Screen Fields995.4.2.16 Console Redirection1015.4.2.17 System Information102Figure 33. Console Redirection Screen102Table 42. Setup Utility – Console Redirection Configuration Fields102Figure 34. System Information Screen103Table 43. Setup Utility – Server Management System Information Fields1035.4.2.18 BMC LAN Configuration104Figure 35. BMC LAN Configuration Screen105Table 44. Setup Utility — BMC configuration Screen Fields1065.4.2.19 Boot Options Screen (Tab)107Figure 36. Boot Options Screen107Table 45. Setup Utility – Boot Options Screen Fields1075.4.2.20 Hard Disk Order1095.4.2.21 Network Device Order109Figure 37. Hard Disk Order Screen109Table 46. Setup Utility — Hard Disk Order Fields1095.4.2.22 Delete EFI Boot Option110Figure 38. Network Device Order Screen110Figure 39. Delete EFI Boot Option Screen110Table 47. Setup Utility — Network Device Order Fields110Table 48. Setup Utility – Delete Boot Option Fields1105.4.2.23 Boot Manager Screen (Tab)1115.4.2.24 Error Manager Screen (Tab)111Figure 40. Boot Manager Screen111Table 49. Setup Utility – Boot Manager Screen Fields1115.4.2.25 Save and Exit Screen (Tab)112Figure 41. Error Manager Screen112Figure 42. Exit Screen112Table 50. Setup Utility — Error Manager Screen Fields112Table 51. Setup Utility — Exit Screen Fields112Loading BIOS Defaults1135. Configuration Jumpers114Figure 43: Jumper Blocks (J9C2, J9F2, J6E1, J6E1, J6E1, J6E1)114Table 52. Server Board Jumpers (J9C2, J9F2, J6E1, J6E1, J6E1, J6E1)114Force BMC Update (J9C2)115BIOS Recovery Mode (J9F2)115Table 53. Force BMC Update Jumper115Password Clear (J6E1)116Table 54. BIOS Recovery Mode Jumper116Table 55. Password Clear Jumper116Force ME Update (J6E1)117Table 56. Force ME Update Jumper117Reset BIOS Settings (J6E1)118Table 57. Reset BIOS Jumper1186. Connector/Header Locations and Pin-out119Power Connectors119System Management Headers119Intel®Remote Management Module 4 (Intel®RMM4 Lite) Connector119Bridge Board Connector119Table 58. Main Power Supply Connector 6-pin 2x3 Connector (J1D1 and J1A2)119Table 59. Intel® RMM4 Lite Connector Pin-out (J7F2)119Table 60. Bridge Board Connector (J6A1)119Power Button120Reset Button121Chassis Identify Button121Power LED121System Status LED121Table 61. Power LED Indicator States121Figure 44. System Status LED (A) and ID LED (B)122Table 62. System Status LED122Chassis ID LED123I/O Connectors124PCI Express* Connectors124Table 63. Chassis ID LED Indicator States124Table 64. PCI Express* x16 Riser Slot 1 Connector (J8F1)124Table 65. PCI Express* x8 Riser Slot 2 Connector (J8A1)126VGA Connector128NIC Connectors128Table 66. PCI Express* Riser ID Assignment128Table 67. VGA External Video Connector (J9D1)128SATA DOM Connectors129Storage Upgrade Key Connector129Table 68. RJ-45 10/100/1000 NIC Connector Pin-out (JA9F1, JA9E1)129Table 69. SATA DOM Connector129Table 70. Storage Upgrade Key Connector (J9F1)129Serial Port Connectors130USB Connectors130QSFP for InfiniBand*130Table 71. Internal 9-pin Serial A (COM1) (J8F5)130Table 72. External USB port Connector (J9C1)130Table 73. QSFP Pin Definition130Fan Headers131Table 74. Baseboard Fan Connector (J1A1)1317. Intel Light-Guided Diagnostics132Front Panel Support132System ID LED132System Status LED132Network Link/Activity LED132Table 75. Network link/activity LED1328.1.4 Dedicated InfiniBand* Link/Activity LED133POST Code Diagnostic LEDs133Table 76. InfiniBand* link/activity LED133Figure 45. Rear Panel Diagnostic LEDs (Block A)1348. Environmental Limits Specification135Processor Thermal Design Power (TDP) Support135Table 77. Server Board Design Specifications1359. Power Supply Specification Guidelines136Power Supply DC Output Connector136Power Supply DC Output Specification136Output Power/Currents136Standby Output136Voltage Regulation136Table 78. Power Supply DC Power Input Connector Pinout (See Table 60)136Table 79. Minimum Load Ratings136Table 80. Voltage Regulation Limits136Dynamic Loading137Capacitive Loading137Grounding137Closed loop stability137Residual Voltage Immunity in Standby mode137Table 81. Transient Load Requirements137Table 82. Capacitive Loading Conditions137Common Mode Noise13810.2.10 Soft Starting13810.2.11 Zero Load Stability Requirements13810.2.12 Hot Swap Requirements13810.2.13 Forced Load Sharing13810.2.14 Ripple/Noise13810.2.15 Timing Reuqirement138Table 83. Ripples and Noise138Figure 46. Turn On/Off Timing (Power Supply Signals)139Table 84. Timing Requirements139Appendix A: Integration and Usage Tips141Appendix B: Integrated BMC Sensor Tables142Table 85. BMC Sensor Table144Appendix C: BIOS Sensors and SEL Data155Table 86. BIOS Sensor and SEL Data155Appendix D: POST Code LED Decoder161Figure 47. Diagnostic LED Placement Diagram161Table 87. POST Progress Code LED Example162Table 88. Diagnostic LED POST Code Decoder163Appendix E: Video POST Code Errors168Table 89. POST Error Messages and Handling168Glossary172Table 90. Glossary172Reference Documents175Size: 5.96 MBPages: 189Language: EnglishOpen manual