User Manual (BBS1200BTS)Table of Contents1. Introduction1Chapter Outline1Server Board Use Disclaimer12. Overview2Intel® Server Board S1200BT Feature Set2Table 1. Intel® Server Board S1200BT Feature Set2Server Board Layout4Figure 1. Intel® Server Board S1200BTL Picture4Server Board Connector and Component Layout5Figure 2. Intel® Server Board S1200BTS Picture5Figure 3. Intel® Server Board S1200BTL Layout6Table 2. Major Board Components6Figure 4. Intel Server Board S1200BTS Layout7Table 3. Major Board Components7Intel® Server Board S1200BTL Mechanical Drawings8Figure 5. Intel® Server Board S1200BTL – Hole and Component Positions9Figure 6. Intel® Server Board S1200BTL – Major Connector Pin Location (1 of 2)10Figure 7. Intel® Server Board S1200BTL – Major Connector Pin Location (2 of 2)11Figure 8. Intel® Server Board S1200BTL – Primary Side Keepout Zone12Figure 9. Intel® Server Board S1200BTL – Secondary Side Keepout Zone13Server Board Rear I/O Layout14Figure 10. Intel® Server Board S1200BT Rear I/O Layout143. Functional Architecture15Figure 11. Intel® Server Board S1200BTL Functional Block Diagram15Processor Sub-System16Intel Xeon Processor E3-1200 Series16Figure 12. Intel® Server Board S1200BTS Functional Block Diagram16Intel® Core™ Processor i3-2100 Series17Intel Turbo Boost Technology17Memory Subsystem17Memory Supported18Post Error Codes18Memory Map and Population Rules19Table 4. Memory Configuration Table20Table 5. UDIMM memory configuration rule20Table 6. UDIMM Maximum configuration20Publishing System Memory21Memory RAS Support21Intel Chipset PCH21I/O Sub-system22Digital Media Interface (DMI)22PCI Express Interface22Serial ATA Support22Low Pin Count (LPC) Interface23USB 2.0 Support23Optional Intel® SAS RAID Module24Integrated Baseboard Management Controller24Integrated BMC Embedded LAN Channel26Figure 13. Integrated BMC Hardware26Optional RMM4 Advanced Management Board27Serial Ports27Floppy Disk Controller27Table 7. Optional RMM4 Advanced Management Board Features27Table 8. Serial B Header (J1B2 on S1200BTL or J8A1 on S1200BTS) Pin-out27Keyboard and Mouse Support28Wake-up Control28Video Support28Intel® Server Board S1200BTL28Table 9. Video Modes28Video for Intel Server Board S1200BTS29Network Interface Controller (NIC)29Gigabit Ethernet Controller 82574L29Gigabit Ethernet PHY 8257929Table 10. Dual Video Modes29MAC Address Definition30Intel® I/O Acceleration Technolgy 2 (Intel® I/OAT2)30Direct Cache Access (DCA)30Intel Virtualization Technology for Directed I/O (Intel VT-d)30TPM (Trusted Platform Module)314. Platform Management32Figure 14. Server Management Bus (SMBUS) Block Diagram32Feature Support33IPMI 2.0 Features33Non-IPMI Features33New Manageability Features34Basic and Optional Advanced Management Features35Table 11. Basic and Advanced Management Features35Enabling Advanced Management Features36Keyboard, Video, and Mouse (KVM) Redirection36Media Redirection38Embedded Web server39Embedded Platform Debug40Data Center Management Interface (DCMI)41Local Directory Authentication Protocol (LDAP)41Thermal Control41Memory Thermal Throttling41Fan Speed Control42Intel® Intelligent Power Node Manager42Overview42Features43Table 12. NM Features43Role of Integrated BMC in NM445. Server Management Capability for Intel® Server Board S1200BTS46Supper I/O46Key Features of supper I/O466. BIOS User Interface47BIOS POST Initialization47BIOS Revision Identification47HotKeys Supported During POST48POST Logo Screen/Diagnostic Screen49Table 13. POST HotKeys Recognized49BIOS Boot Pop-up Menu50BIOS Setup Utility50BIOS Setup Operation50Table 14. BIOS Setup Page Layout51Table 15. BIOS Setup: Keyboard Command Bar52BIOS Setup Utility Screens53Table 16. Screen Map54Figure 15. Main Screen56Figure 16. Advanced Screen59Figure 17. Processor Configuration Screen62Figure 18. Memory Configuration Screen68Figure 19. Mass Storage Controller Configuration Screen71Figure 20. Serial Port Configuration Screen72Figure 21. USB Configuration Screen73Figure 22. PCI Configuration Screen74Figure 23. System Acoustic and Performance Configuration75Figure 24. Security Screen75Figure 25. Server Management Screen (S1200BTL)76Figure 26. Server Management Screen (S1200BTS)77Figure 27. Console Redirection Screen77Figure 28. System Information Screen (S1200BTL)78Figure 29.System Information Screen (S1200BTS)79Figure 30. BMC LAN Configuration Screen (S1200BTL)80Figure 31. Hardware Monitor Screen, Auto Fan Control (S1200BTS)81Figure 32. Hardware Monitor Screen, Manual Fan Control (S1200BTS)81Figure 33. Realtime Teperature and Voltage Status Screen (S1200BTS)82Figure 34. Boot Options Screen83Figure 35. Hard Disk Order Screen84Figure 36. CDROM Order Screen84Figure 37. Floppy Order Screen85Figure 38. Network Device Order Screen85Figure 39. BEV Device Order Screen86Figure 40. Add EFI Boot Option Screen86Figure 41. Delete EFI Boot Option Screen87Figure 42. Boot Manager Screen87Figure 43. Error Manager Screen88Figure 44. System Event Log Screen (S1200BTS)88Figure 45. Exit Screen897. Connector/Header Locations and Pin-outs90Board Connector Information90Table 17. Board Connector Matrix on S1200BTL90Power Connectors91Table 18. Board Connector Matrix on S1200BTS91Table 19. Baseboard Power Connector Pin-out (J9G1)91System Management Headers92NIC connector92Table 20. SSI Processor 8-PIN Power Connector Pin-out (J9A1)92Table 21. Intel® RMM4 lite Connector Pin-out (J4B1)92Table 22. Dedicated NIC connector for RMM492LPC/IPMB Header93HSBP Header93SGPIO Header93Front Control Panel Connector93Table 23. LPC/IPMB Header Pin-out (J1H5)93Table 24. HSBP Header Pin-out (J1J2)93Table 25. SGPIO Header Pin-out (J1J3 on S1200BTL and J2J2 on S1200BTS)93S1200BTS)93Power Button94Reset Button95System Status Indicator LED95Table 27. System Status LED Indicator States95I/O Connectors96VGA Connector96Rear NIC and USB connector96Table 28. VGA Connector Pin-out96Table 29. RJ-45 10/100/1000 NIC Connector Pin-out96SATA97SAS Connectors97Table 30. RJ-45 10/100/1000 NIC Connector Pin-out (J6A1)97Table 31. 6Gb/s SATA Connector Pin-Out97Table 32. 3Gb/s SATA Connector Pin-out97Serial Port Connectors98Table 33. SAS Connector Pin-out (J2H1)98Table 34. External Serial A Port Pin-out (J8A1)98Table 35. Internal 9-pin Serial B Header Pin-out (J1B2)98USB Connector99Table 36. Internal USB Connector Pin-out ( J1E1, J1D1)99Table 37. Pin-out of Internal USB Connector for low-profile Smart module (J3F2)99PCI Express* Slot/PCI Slot/Riser Card Slot100Table 38. Pin-out of adaptive riser slot/PCI Express slot 6100Table 39. Three PCI Express* x8 connectors (J2B2, J3B1 and J4B2)102Table 40. One PCI X32 connector (J1B1)102Fan Headers103Table 41. SSI 4-pin Fan Header Pin-out1038. Jumper Blocks104Figure 46. Jumper Blocks (J4A2, J1F1, J1F3, J1F2, and J1E2) on S1200BTL104Table 42. Server Board Jumpers (J1F1, J1F2, J1F3, J1E2, and J4A2) on S1200BTL104CMOS Clear and Password Reset Usage Procedure105Figure 47. Jumper Blocks (J2G1, J1G1, J1H3, and J2J1) on S1200BTS105Table 43. Server Board Jumpers (J2G1, J1G1, J1H3, and J2J1) on S1200BTS105Clearing the CMOS106Clearing the Password106S1200BTL)107ME Force Update Jumper107BIOS Recovery Jumper1089. Intel Light Guided Diagnostics109System Status LED (Only for S1200BTL)109Post Code Diagnostic LEDs109Table 44. Front Panel LED Behavior Summary109Figure 48. POST Code Diagnostic LED Location11010. Design and Environmental Specifications111Intel Server Board S1200BT Design Specifications111Board-level Calculated MTBF111Processor Power Support111Table 45. Server Board Design Specifications111Power Supply Output Requirements112Table 46. Intel® Xeon® Processor TDP Guidelines112Table 47. 350-W Load Ratings112Grounding113Standby Outputs113Remote Sense113Voltage Regulation113Dynamic Loading113Table 48. Voltage Regulation Limits113Table 49. Transient Load Requirements113Capacitive Loading114Closed-loop Stability114Common Mode Noise114Ripple / Noise11410.3.10 Timing Requirements114Table 50. Capacitve Loading Conditions114Table 51. Ripple and Noise114Figure 49. Output Voltage Timing115Table 52. Output Voltage Timing115Figure 50. Turn On/Off Timing (Power Supply Signals)116Table 53. Turn On/Off Timing11610.3.11 Residual Voltage Immunity in Standby Mode11710.3.12 Protection Circuits117Table 54. Over-Current Protection (OCP)117Table 55. Over-voltage Protection (OVP) Limits117Appendix A: Integration and Usage Tips119Appendix B: Integrated BMC Sensor Tables120Table 56. BMC Core Sensors122Appendix C: POST Code Diagnostic LED Decoder129Table 57. POST Progress Code LED Example129Table 58. POST Progress Codes129Appendix D: POST Code Errors133Table 59. POST Error Codes and Messages133Table 60. POST Error Beep Codes135Appendix E: Supported Intel® Server Chassis136Glossary137Reference Documents141Size: 3.74 MBPages: 153Language: EnglishOpen manual