User ManualTable of ContentsContents3Before You Begin71.1 About this manual71.2 About ProLink II software71.2.1 Supported transmitters71.2.2 Uses of ProLink II81.3 ProLink II requirements81.3.1 PC requirements81.3.2 Installation kits81.4 Determining your transmitter type91.5 Micro Motion customer service9Installation and Setup132.1 Overview132.2 Installation and setup132.2.1 Ensure required privileges132.2.2 Install the ProLink II software142.2.3 Generate the temporary license142.2.4 Determine your connection type152.2.5 Install the signal converter and connect the wires172.2.6 Configure ProLink II connection parameters and connect to the transmitter322.2.7 Obtain and configure a site key352.3 Troubleshooting the ProLink II installation362.3.1 Insufficient privileges362.3.2 Missing or corrupt registry entries362.4 Troubleshooting the ProLink II connection372.4.1 OPC server or OPC client issues372.4.2 Other issues37Using ProLink II Software393.1 Overview393.2 ProLink II user interface393.3 Startup393.3.1 Connecting to a transmitter403.3.2 Disconnecting423.4 ProLink II help system423.5 Viewing installed options423.6 Viewing process data433.7 Viewing and resetting totalizers and inventories433.8 Viewing meter status443.9 Viewing and acknowledging alarms453.9.1 Viewing alarms453.9.2 Acknowledging alarms473.10 Managing the ProLink II license473.10.1 Transferring to same PC473.10.2 Transferring to different PC47Initial Transmitter Startup Procedures494.1 Overview494.2 Loop tests494.3 Trimming the milliamp (mA) output(s)524.4 Zeroing the meter54Transmitter Configuration, Characterization, and Calibration575.1 Overview575.2 Using configuration files575.2.1 Saving a configuration file to a PC575.2.2 Loading a configuration file to a transmitter585.3 Configuring a transmitter585.3.1 Using the Gas Unit Configurator tool605.4 Characterizing the meter615.4.1 When to characterize615.4.2 Characterization parameters615.4.3 How to characterize645.5 Calibrating the meter645.5.1 When to calibrate655.5.2 Density calibration655.5.3 Temperature calibration695.6 Compensating for pressure705.6.1 Options705.6.2 Pressure correction factors705.6.3 Configuration705.7 Compensating for temperature715.8 Configuring polling72Meter Verification736.1 Overview736.2 Running the meter verification test736.2.1 First panel: Sensor and Transmitter Configuration736.2.2 Second panel: Test Definition756.2.3 Third panel: Start766.2.4 Fourth panel: Test Results796.2.5 Fifth panel: Report80Data Logger837.1 Overview837.2 Using Data Logger837.2.1 Defining the log file837.2.2 Specifying log contents847.2.3 Starting and stopping the logging function857.2.4 Data Logger tools85Transmitter Terminal Reference87A.1 Overview87A.2 Transmitter terminal diagrams88Configuring the Discrete Batch Application93B.1 About this appendix93B.2 About discrete batching93B.3 Discrete batch configuration93B.3.1 Flow source95B.3.2 Control options96B.3.3 Configure presets98B.3.4 Batch control methods100B.4 Running a batch103B.5 Performing Batch AOC calibration104Index105Size: 2.36 MBPages: 110Language: EnglishOpen manual