C.3 Drawing a Ramp/Soak Profile
Ramp/soak profile example
Before you perform the actual configuration, we recommend that you draw your Ramp/Soak profiles in the
space provided on the blank graphs and fill in the associated information on the worksheet. An example of
a Ramp-Soak Profile using the first twelve segments for Program 1 is shown in Figure C-1. Start setpoint
in this example is at 200
space provided on the blank graphs and fill in the associated information on the worksheet. An example of
a Ramp-Soak Profile using the first twelve segments for Program 1 is shown in Figure C-1. Start setpoint
in this example is at 200
°F.
Figure C-1 Ramp/Soak Profile Example
Prompt Function Segment Value
Prompt Function Segment Value
START1
Start Seg.
1
SG6 SP
Soak SP
6
250
END 1
End Seg.
12
SG6 TI
Soak Time
6
3 hr:0 min
RECYCL
Number of
Recycles
Recycles
2
SG7 RP
Ramp
7
2 hr:30 min
SOKDEV
Deviation Value
0
SG8 SP
Soak SP
8
500
RP UNIT
Ramp Units
TIME
SG8 TI
Soak Time
8
0 hr:30 min
END ST
Program
State at end
State at end
HOLD
SG9 RP
Ramp
9
0
SG1 RP
Ramp
1
1 hr
SG10SP
Soak SP
10
400
SG2 SP
Soak SP
2
300
SG10TI
Soak Time
10
0 hr:30 min
SG2 TI
Soak Time
2
1 hr:30 min
SG11RP
Ramp
11
3 hr:30min
SG3 RP
Ramp
3
1 hr
SG12SP
Soak SP
12
200
SG4 SP
Soak SP
4
400
SG12TI
Soak Time
12
0 hr:30 min
SG4 TI
Soak Time
4
1 hr
SG5 RP
Ramp
5
1 hr:30 min.