Dacor DHW361 Installation Guide

Page of 16
8
Installation Instructions
Connecting the Duct Work
 WARNING
Do not use screws to attach the duct work to the hood 
exhaust outlet. Use duct tape only. Screws may prevent 
the damper flaps on the top of the hood from opening.
If installing the unit with a recirculating kit, skip to Final 
Electrical Installation. Otherwise, install the duct work 
between the hood exhaust and the previously installed 
duct work. Attach the duct to the hood exhaust with duct 
tape alone. Use sheet metal screws (not provided) and 
duct tape on the remaining joints.
Final Electrical Installation
 WARNING
•  To avoid electric shock or fire hazard, prior to con-
necting the electrical wiring to the hood, make sure 
that power to the hood power supply line is turned 
off at the circuit breaker panel or fuse box.
•  Improper connection of the hood electrical wiring 
may create an electric shock or fire hazard and may 
result in damage to the hood’s electrical system. 
See page 3 for specifications.
•  Do not ground the hood to the neutral (white) power 
supply wire. Connect the hood ground wire to a 
separate, proper ground wire installed by a licensed 
electrician.
•  Make sure all wire used is capable of handling the 
total connected load. See page 3.
Connect the house power supply wires to the wires 
coming out of the hood junction box, inside the chim-
ney:
1.  Connect the white wire 
from the hood to the 
neutral (white) power 
supply wire.
2.  Connect the black wire 
from the hood to the hot 
(black) power supply 
wire.
3.  Connect the green 
and yellow wire from 
the hood to the house 
ground (green) wire from 
the junction box.
Final Chimney Assembly
 WARNING
Be careful not to pinch the electrical wires while 
assembling the chimney.
1.  Remove the protective plastic covering from both 
pieces of the chimney assembly. Do not remove the 
protective tape strips from the inside of the chimney. 
They protect the telescoping pieces from scratching 
during installation.
2.  Carefully slide both sections together so that only the 
vents on the top section show.
3.  Hold the chimney vertically with the vents up.
Chimney
Chimney 
mounting 
bracket
Vent
Duct work
Hood
House power 
supply wires
Wires to blower 
inside hood 
chassis