Bosch Appliances Webcam 3922 988 43318 User Manual
2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation and Operating Manual | Chapter 10 - Installation Techniques
en | 10-14
Computer Based Systems
10.7.1 PC Network System
In installations where more than one PC operator control position is required, an additional PC can
be connected via a ‘Peer-to-Peer’ Network, using a separate cable. PC’s connected in this method
both require an Ethernet card installed in the computer with ‘Microsoft operating systems:
Windows® 95, 98 2000, NT 4.0 or XP Professional. See also
be connected via a ‘Peer-to-Peer’ Network, using a separate cable. PC’s connected in this method
both require an Ethernet card installed in the computer with ‘Microsoft operating systems:
Windows® 95, 98 2000, NT 4.0 or XP Professional. See also
. DCN Control Using
Personal Computers
NOTE:
Information is available on request concerning ‘Microsoft® Windows® and for
using the Ethernet card .
shows a typical configuration with an additional PC installed.
Ethernet requirements
•
Ethernet card (3Com recommended)
These cards have to be installed on each PC on a free interrupt e.g 10.
These cards have to be installed on each PC on a free interrupt e.g 10.
•
‘Microsoft Windows® 95, 98, NT 4.0, 2000 or XP Professional.
•
Connection between a server and a client PC:
- UTP cable or
- 50 Ohm coax cable with:
- Two 50 Ohm T-pieces
- Two 50 Ohm terminating plugs
- 50 Ohm coax cable with:
- Two 50 Ohm T-pieces
- Two 50 Ohm terminating plugs
NOTE:
The DCN software needed for this function must be version 6.0 or higher.
Software requirements on the PC’s
Server PC:
•
LBB 3590 Start-up
•
LBB 3585 System Installation
•
One or more software application modules to control the required functions
Client PC:
•
LBB 3590 Start-up
•
One or more software application modules to control the required functions
Audio monitoring on the client PC
If the audio monitoring function is also required on the slave PC, a language selector panel can be
used or an additional PC network card LBB 3510/00 must be installed in the client PC.
used or an additional PC network card LBB 3510/00 must be installed in the client PC.
Port 1
Rec.
Line
In
Out
In
Out
Symmetrical
Trunk
115V-T4A 230V -T2A
Port 2
115
V T4A
230V
T2A
Output 1
Output 2
Output 3
Output 4
Trunk
Tap-off
LBB 3500/15 or LBB 3500/35
PCF
≤
180
LBB 4116/xx
LBB 4114/00
PC Network Card
LBB 3510/00
LBB 3510/00
Ethernet
Card
Card
Ethernet
Card
Card
LBB 3508/00
PCF
≤
90
LBB 4116/xx
Ethernet link
SERVER PC
CLIENT PC
NOTE: The above example uses the IN-DIRECT (PC-Network card LBB 3510/00)
method of trunk-line cabling connecting the PC to the DCN.