BladeSymphony 1000 Architecture
 
White Paper
www.hitachi.com
Serviceability Features
Switch & Management Module
The Switch & Management Module is designed to control the system unit and monitor the environment. 
Figure 28 shows the block diagram of the module. This module and other system components are 
connected through I2C or other busses. 
Figure 28. Switch & Management Module components
The Switch & Management Module contains the service processor (SVP) which controls the system 
and monitors the environment. A SVP is connected to the server blades or another SVP on the other 
Switch & Management Module (if mounting two Switch & Management Modules) through the 
backplane interfaced by 100M/10M Ethernet. Further, an SVP is connected to the server blades, 
another SVP or the I/O modules through the backplane by an I2C interface. The SVP performs tasks 
including system control, monitoring, and notice of a fault. The SVP is equipped with a console 
interface, which provides a user interface for maintaining and managing the system. Table 12 defines 
the components of the Switch & Management Module. 
Two Switch & Management Modules can be installed on one chassis. In this case, the main SVP 
normally performs the SVP function. Health checking works between the main and sub-SVP as they 
monitor each other. If the main SVP fails, the sub-SVP takes over operation.
The Switch & Management Module houses the gigabit Ethernet switch, to which the gigabit Ethernet 
port of each server blade is connected over the backplane. When two Switch & Management Modules 
are installed, each switch operates independently. 
MAINT1 Port
Serial I/F for on 
site service
NV-
SRAM
1 MB
ECC
Ether
Controller
Reserved 3ports for
- SVP redundant
- Extended switch
I2C MUX
I2C
Controller
To Panel
FPGA
Buffer
Flash
16 MB
(OS)
GLAN0-3 Port
1000Base-T
SVP-LAN Port
SVP-LAN0: Exclusively for maintenance
LAN connection
SVP-LAN1: For management
To CPU Module
#0-7
I/O Module #0,#1
SAFTE#0-3 (to HDD Mod )
SDRAM
128 MB
ECC
PCI Bus
Compact
Flash
128 MB
GB Ether
Switch
PWCTRL1 Port
Power control connector of 
multiple chassis
SerDes GB I/F
Management LAN
I2C I/F
RTC
I2C
Controller
From CPU
module #0-7
From CPU
module #0-7
Buffer
Ether
Controller
{
{
For Power
Supply Control
Ether Switch
Micro-
processor
(Not opened 
  to user)