Hitachi RAC-25FXA RAC25FXA User Manual
Product codes
RAC25FXA
13-7
13.3 ELECTRICAL WIRING FOR SINGLE INVERTER UNIT
WARNING:
–
The appliance must be earthed
–
Power supply shall be connected at the rated
voltage; otherwise the unit will be broken or could
not reach the specified capacity.
voltage; otherwise the unit will be broken or could
not reach the specified capacity.
13.3.1 PROCEDURES OF WIRING
•
Applicable models
RAK-18PSA/RAC-18WSA
RAK-18PSAN/RAC-18WSAN
RAK-25PSA/RAC-25WSA
RAK-25PSAN/RAC-25WSAN
RAK-35PSA/RAC-35WSA
RAK-35PSAN/RAC-35WSAN
•
Applicable models :
RAK-50PXA/RAC-50WXA
RAK-50PPA/RAC-50WPA
RAK-50PPA/RAC-50WPA
•
Applicable models
RAF-25PXA/RAC-25FXA
RAK-25PPA/RAC-25WPA
RAF-35PXA/RAC-35FXA
RAK-35PPA/RAC-35WPA
RAF-50PXA/RAC-50FXA
RAK-18PEA/RAC-18WEA
RAF-25RPA/RAC-25FPA
RAK-25PEA/RAC-25WEA
RAF-35RPA/RAC-35FPA
RAK-35PEA/RAC-35WEA
RAF-50RPA/RAC-50FPA
RAK-50PEA/RAC-50WEA
RAK-25PXA/RAC-25WXA
RAK-18PSPA/RAC-18WSPA
RAK-35PXA/RAC-35WXA
RAK-25PSPA/RAC-25WSPA
RAK-18PPA/RAC-18WPA
RAK-35PSPA/RAC-35WSPA
•
Applicable models :
RAK-60PPA/RAC-60WPA
RAD-50PPA/RAC-50DPA
RAK-70PPA/RAC-70WPA
RAD-60PPA/RAC-60DPA
RAD-70PPA/RAC-70DPA
When removing the connecting wires for the indoor unit,
please remove the low cover panel in front of the unit
WARNING:
–
The naked part of the wire core should be10 mm and
fix them tightly to the terminal. Then try to pull the
individual wire to check if the contact is tight. Improper
insertion may cause the terminal to burn.
fix them tightly to the terminal. Then try to pull the
individual wire to check if the contact is tight. Improper
insertion may cause the terminal to burn.
–
Be sure to use only power cables approved from the
authorities from your country. For example in
Germany: Cable type : NYM 3x1.5mm
authorities from your country. For example in
Germany: Cable type : NYM 3x1.5mm
2
–
Please refer to the installation manuals for wire
connection to the terminals of the units. The cabling
must meet the standards of electrical installation
connection to the terminals of the units. The cabling
must meet the standards of electrical installation
–
There is a AC voltage of 230V between the L and N
terminals. Therefore, before servicing, be sure to
remove the plug from the AC outlet or switch off the
main switch.
terminals. Therefore, before servicing, be sure to
remove the plug from the AC outlet or switch off the
main switch.
L N C D
A B C D
C D
B
A
N
L
Line cord
Connecting cord
φ2.5
φ1.6 Or φ2.0
Indoor Unit
Outdoor Unit
Indoor Unit
Connecting
Cord
AC 220-230
1 Phase 50Hz
Ø2.0