Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 158 of 256 
15.07.2002 
 
5.16  AT+CSMS  Select Message Service 
Test command 
AT+CSMS=? 
Response 
+CSMS: (list of supported
 <service>s) OK 
Parameter 
See write command 
 
Read command 
AT+CSMS? 
Response 
+CSMS: <service>,<mt>,<mo>,<bm> OK 
Parameter 
See write command 
 
Write command 
AT+CSMS= 
<service> 
Response 
+CSMS: <mt>,<mo>,<bm> OK 
If error is related to ME functionality: 
+CMS ERROR: <err> 
Parameter 
<service>
 
GSM 03.40 and 03.41 (the syntax of SMS AT commands is 
compatible with GSM 07.05 Phase 2 version 4.7.0; Phase 2+ 
features which do not require new command syntax may be 
supported, e.g. correct routing of messages with new Phase 2+ 
data coding schemes) 
 
GSM 03.40 and 03.41 (the syntax of SMS AT commands is 
compatible with GSM 07.05 Phase 2+ version; the requirement 
of <service> setting 1 is mentioned under corresponding com-
mand descriptions).  
 
<mt> Mobile 
Terminated 
Messages: 
 0 
Type 
not 
supported 
 
1 Type 
supported 
<mo> Mobile 
Originated 
Messages: 
 0 
Type 
not 
supported 
 
1 Type 
supported 
<bm> 
Broadcast Type Messages: 
 0 
Type 
not 
supported 
 
1 Type 
supported 
 
Reference 
GSM 07.05 
Note 
If CSMS Mode is switched from Phase 2+ to Phase 2 and one or more CNMI Pa-
rameter are Phase 2+ specific a '+CMS ERROR: unknown error' will appear. It is 
recommended to switch the CNMI Parameters to Phase 2 specific values before 
entering Phase 2.