12.2 Output Status for Errors and Alarms 
 
Error indication  Measured value 
indication 
Current output 
(4-20mA) 
Totalization 
pulse output
Remarks 
ROM ERROR 
 (Note 1) 
 
(Note 3) 
Stopped 
After power-up,   
no measurement starts. 
RAM ERROR 
 
(Note 3) 
Stopped 
After power-up,   
no measurement starts. 
PARAMETER 
FAILURE 
 
(Note 2) 
Zero 
(Note 3) 
Stopped 
――――――― 
EXC CUR 
OPEN 
Zero 
(Note 3) 
Stopped 
Still water zero adjustment   
cannot be performed. 
EXC CUR 
ERROR 
Zero 
(Note 3) 
Stopped 
Still water zero adjustment   
cannot be performed. 
ADC ERROR 
Zero 
(Note 3) 
Stopped 
Still water zero adjustment   
cannot be performed. 
INVALID 
TOTAL 
Measured data 
Measured data 
Measured data 
The error message   
disappears if you clear   
(reset) the totalizer count. 
HIGH ALARM 
Measured data 
Measured data 
Measured data 
――――――― 
LOW ALARM 
Measured data 
Measured data 
Measured data 
――――――― 
HIGH HIGH 
ALARM 
Measured data 
Measured data 
Measured data 
――――――― 
LOW LOW 
  ALARM 
Measured data 
Measured data 
Measured data 
――――――― 
Note 1: The display and output may not be correct depending on the nature of the ROM error. 
Note 2: If a parameter failure relating to the current output occurs, the current output may not become 
the value as specified by the setting when an alarm occurs. 
Note 3: The current output value used in case an alarm occurs will be output. For setting method, see 
8.2.16, “4
20mA Alarm Output Setting.”