Samsung SSA-S1000 User Manual
English
English _ 11
INSTALLATION AND EXTERNAL CONNECTION
Output Connection
- To connect the power supply unit
Connect the DC+12V to the red line.
Connect GND to the black line.
- To connect the door lock device
Connect the plus(+) line of the lock device to DC+12V.
Connect the minus(-) line of the lock device to the white line.
Connect the minus(-) line of the lock device to the white line.
- To connect the alarm device
Connect the plus(+) line of the alarm device to DC+12V.
Connect the minus(-) line of the alarm device to the purple line.
Connect the minus(-) line of the alarm device to the purple line.
- To specify the lock type
POWER FAIL SAFE: Connect the yellow line to GND.
POWER FAIL SECURE: Leave the yellow line in the fl oating state.
1.
2.
1.
2.
2.
1.
2.
2.
DOOR LOCK OUT
(white)
ALARM OUT
(purple)
Door Lock
Alarm Device
Cathode
Anode
1N4004 ~ 1N4007 or equiv.
GND
DC +12V
Lock Type Select
(yellow)
DC 12V(+) POWER