Samsung Gas Cooktop (NAK6550 Series) Installation Guide

Page of 84
English  23
Installation instructions
Supplied parts
The following parts make up the LP conversion kit:
 
DG69-00261B
LR(WHT)
LF(WHT)
RF(RED)
RR(YEL)
DG96-00502B
(ASSY NOZZLE KIT)
ORIFICES/ORIFICES/ORIFICIOS
CENTER
Out(PUR)
In(GRAY)
 
DG69-00261A
LR(WHT)
LF(WHT)
RF(RED)
RR(YEL)
DG96-00502A
(ASSY NOZZLE KIT)
ORIFICES/ORIFICES/ORIFICIOS
CENTER
Out(WHT)
In(GRAY)
NA30K6550T*/ NA36K6550T*
NA30K7750T*/ NA36K7750T*
The all orifices’ positions are marked on the provided sheet. The spud in the 
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion 
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS 
(LP Gas [Propane] 10 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
RF
11,500
1.04
LF
7,500
0.83
RR
4,000
0.62
LR
7,500
0.83
Center
1
14,500
In: 0.46 / Out: 0.74 (2 pcs)
Center
2
16,500
In: 0.46 / Out: 0.83 (2 pcs)
1
Model NA30K6550T* / NA36K6550T*
2
Model NA30K7750T* / NA36K7750T*
BURNER ORIFICE SIZES AND OUTPUT RATINGS 
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
RF
13,000
1.64
LF
9,500
1.40
RR
5,000
1.01
LR
9,500
1.40
Center
1
19,000
In: 0.70 / Out: 1.30 (2 pcs)
Center
2
22,000
In: 0.85 / Out: 1.36 (2 pcs)
1
Model NA30K6550T* / NA36K6550T*
2
Model NA30K7750T* / NA36K7750T*
NOTE
115
Orifice markings:
115 – Denotes 1.15 mm orifice size opening.
Install_NA9300K_DG68-00841A-01_EN+MES+CFR.indb   23
12/12/2016   9:31:44 PM