Intel SC5250-E User Manual

Page of 73
Environmental Limits 
Intel® Entry Server Chassis SC5250-E 
  
Revision 
1.02 
Intel order number C32881-001 
 
54
11. Environmental Limits 
11.1  System Office Environment 
Table 11. System Office Environment Summary 
Parameter 
Limits 
Operating Temperature 
+5oC to +35oC with the maximum rate of change not to exceed 10oC per hour.  
Non-Operating Temperature 
-40oC to +70oC 
Non-Operating Humidity 
95%, non-condensing @ 30oC 
Acoustic noise 
50 dBA in a typical office ambient temperature (18-25C) 
Operating Shock 
No errors with a half sine wave shock of 2G (with 11-millisecond duration). 
Package Shock 
Operational after a free fall, 18 – 24 inch depending on the weight. 
ESD 
15kV per Intel Environmental Test Specification 
11.2  System Environmental Testing 
The system will be tested per the Environmental Standards Handbook, Intel Doc.#662394-05.  
These tests shall include: 
• 
Temperature Operating and Non-Operating 
• 
Humidity Non-Operating 
• 
Packaged Shock 
• 
Packaged and Unpackaged Vibration 
• 
AC Voltage, Frequency, and Source Interrupt 
• 
AC Surge 
• 
Acoustics 
• 
Electrostatic Discharge (ESD) 
• 
EMC Radiated Investigation