Honeywell Liquid Cooled 25kW Home Standby Generator Owner's Manual

Page of 72
SPECIFICATIONS
STATIONARY EMERGENCY GENERATOR
Type......................................................................Synchronous
Rotor Insulation .............................................................Class H
Stator Insulation ............................................................Class H
Telephone Interference Factor (TIF) .................................. < 50
Alternator Output Leads 3-phase ..................................... 4-wire
Bearings ..................................................................Sealed Ball
Coupling ................................................................Flexible Disc
Load Capacity (Standby Rating) .....................................25kW*
*
  NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE 
J1349, ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate 
with natural gas and generator specific settings.
Excitation System ............................................................Direct
Generator Output Voltage/kW - 60 Hz  kW 
Amp  CB Size
  120/240V, 1-phase, 1.0 pf 
25 
104 
125
  120/208V, 3-phase, 0.8 pf 
25 
87 
100
  120/240V, 3-phase, 0.8 pf 
25 
75 
90
Generator Locked Rotor KVA Available @ Voltage Dip of 35%
 25kW
42 KVA
ENGINE
Make ........................................................................... Generac
Model ......................................................................... In Line 4
Cylinders and Arrangement .....................................................4
Displacement ............................................................... 2.4  Liter
Bore............................................................ 86.5 mm (3.41 in.)
Stroke .......................................................... 100 mm (3.94 in.)
Compression Ratio....................................................... 9.5-to-1
Air Intake System ......................................... Naturally Aspirated
Valve  Seats ................................................................ Hardened
Lifter  Type .................................................................. Hydraulic
Spark Plug Gap ...................1.07 - 1.17mm (0.042 - 0.46 inch)
Engine Parameters
Rated Synchronous RPM .......................................60 Hz, 1800
Exhaust System
Exhaust Flow at Rated Output 60 Hz (22/27kW) ....165/180 cfm
Exhaust Temp. at Rated Output (22/27kW) ........... 900°/1000° F
Combustion Air Requirements (Natural Gas)
Flow at rated power, 60 Hz .............................................68 cfm
Governor
Type...........................................................................Electronic
Frequency  Regulation .............................................Isochronous
Steady State Regulation ..............................................± 0.25%
Engine Lubrication System
Type of Oil Pump ...............................................................Gear
Oil Filter ......................................... Full Flow Spin-on, Cartridge
Crankcase Oil Capacity ....................................... 5.25 U.S. qts.
(including oil filter capacity)
COOLING SYSTEM
Type............................................. Pressurized Closed Recovery
Water Pump ............................................................. Belt Driven
Fan Speed ..................................................................1980 rpm
Fan Diameter ...........................................................18.1 inches
Fan  Mode ....................................................................... Pusher
Air Flow (inlet air including alternator and
  combustion air) ................................................. 2400 ft
3
/min.
Coolant Capacity ................................................. (3.0 U.S. gal.)
Heat Rejection to Coolant (25kW) .......................105,000 Btu/h
Maximum Operating Air Temp. on Radiator ......... 60° C (150° F)
Maximum Ambient Temperature ......................... 50° C (140° F)
FUEL SYSTEM
Type of Fuel ....................................Natural Gas, Propane Vapor
Carburetor............................................................... Down Draft
Secondary Fuel Regulator............................................ Standard
Fuel Shut-off Solenoid ................................................. Standard
Operating Fuel Pressure  ................. 5 in. - 14 in. Water Column
Fuel Consumption - ft
3
/hr (Natural Gas/LPV)
 
Exercise 25%  50%  75%  100%
 
Cycle Load  Load  Load  Load
25kW  42/16  108/43  197/78  287/114 359/143
ELECTRICAL SYSTEM
Battery Charge Alternator ......................................12V, 30 Amp
Static Battery Charger ..................................................2.5 Amp
Recommended Battery .................................Group 26, 525CCA
System Voltage ............................................................ 12 Volts
Voltage Regulator
Type...........................................................................Electronic
Sensing ................................................................ Single-phase
Regulation ........................................................................±  1%
Features ......................................... Adjustable Voltage and Gain
Power Adjustment for Ambient Conditions
Temperature Deration
  3% for every 10° C above °C (25kW) ..................................25
  1.65% for every 10° above °F (25kW) ..........................104/77
Altitude Deration
  1% for every 100 m above m (25kW) ...............................183
  3% for every 1000 ft. above ft. (25kW) ....................2500/600
Controller ................................................................. Nexus
Specifications
6-1
GenSpec092  Rev