KitchenAid KDRS483VSS Installation Guide

Page of 52
15
4-wire connection: Power supply cord
Use this method for:
 
New branch-circuit installations (1996 NEC)
 
Mobile homes
 
Recreational vehicles
 
In an area where local codes prohibit grounding through 
the neutral.
1.  Remove the ground-link screw from the range frame. 
Save the ground-link screw. Bend the ground link away 
from the range so that it does not contact the range.
2.  Connect the green ground wire from the power supply 
cord to the range using the ground-link screw. The ground 
wire must be attached first and must not contact any other 
terminal.
3.  Use a 
1
/
4
" nut driver to remove the hex washer head screws 
from the terminal blocks.
4.  Connect the neutral (center) wire to the center terminal 
connector using one of the hex washer head screws.
Securely tighten screw for proper electrical connection.
5.  Connect the other 2 wires (lines 1 and 2) to the outer 
aluminum terminal blocks.
6.  Securely tighten screws for proper electrical connection.
7.  Tighten strain-relief screws.
8.  Replace terminal block cover.
3-wire connection: Power supply cord
Use this method only if local codes permit connecting cabinet-
ground conductor to neutral wire of power supply cord.
1.  Use a 
1
/
4
" nut driver and remove the hex washer head 
screws from the aluminum terminal blocks.
2.  Connect the neutral (center) wire to the center terminal 
connector using one of the hex washer head screws. 
Securely tighten screw for proper electrical connection.
3.  Connect the other 2 wires (lines 1 and 2) to the outer 
terminal screws on the terminal block.
4.  Tighten strain-relief screws.
5.  Replace terminal block cover.
Install Water Filtration System
(on some models)
Install Model W10049700 Water Filter
1.  Install the water filter near the cold water supply pipe under 
the kitchen sink to filter the cold water.
IMPORTANT: Be sure to allow a minimum clearance of 
1
1
/
2
" (3.8 cm) under the filter system for removing the filter 
cartridge.
Make sure that the water filter assembly is installed in the 
upright position.
Typical Installation Configuration
NOTE: For unique installations, contact a licensed plumber.
In Massachusetts, a licensed plumber is required and the 
Commonwealth of Massachusetts Plumbing Code 248-CMR 
will be adhered to.
A
B
A.  Ground-link screw
B.  Ground link bent away from range
A
B
C
D
E
F
G
H
I
A.  Line 1
B.  Green ground wire
C.  Ground-link screw
D.  Hex washer head screw
E.  Silver-colored terminal 
block screw
F.  Ground link
G. Neutral (center) wire
H.  Line 2
I.  UL Listed strain relief 
and 40- or 50-amp range 
power supply cord
A
B
C
D
E
F
G
A.  Line 1
B.  Ground link
C.  Hex washer head screw
D.  Silver-colored terminal 
block screw
E.  Neutral (center) wire
F.  Line 2
G. UL Listed strain relief 
and 40- or 50-amp range 
power supply cord
Filter
Assembly
Cold  water
supply
Hot Cold
Water supply
line to cold
water supply
Water supply
line to oven