INSTALLATION
ENGLISH
Connecting the Range to Gas
Shut off the range gas supply valve before removing 
the old range and leave it off until the new hook-up 
has been completed.
Because hard piping restricts movement of the range, 
the use of a CSA International-certified flexible metal 
appliance connector should be used unless local 
codes require a hard-piped connection.
A manual valve shall be installed in an accessible 
location in the gas piping external to the appliance 
for the purpose of turning on or shutting off gas to the 
appliance.
Never reuse an old connector when installing a new 
range.
To protect against gas leaks, use a qualified pipe joint 
sealant on all external threads.
1
Install a male 
1
/
2
" or 
3
/
4
" flare union adapter to the 
NPT internal thread of the manual shut-off valve, 
taking care to back-up the shut-off valve to keep 
it from turning.
2
Install a male 
1
/
2
" flare union adapter to the 
1
/
2
NPT internal thread at the inlet of the pressure 
regulator. Use a backup wrench on the pressure 
regulator fitting to prevent damage.
In an emergency situation or if you want to shut 
off the gas supply, close the regulator valve by 
positioning the lever as shown in the figure below.
Lever’s open 
position
Lever’s closed 
position
3
Connect a flexible metal appliance connector to 
the adapter on the range. Position the range to 
permit connection at the shut-off valve.
4
When all connections have been made, be sure 
all range controls are in the 
Off position and turn 
on the main gas supply valve. Gas leaks may 
occur in your system and create a hazard. Gas 
leaks may not be detected by smell alone.
Check all gas connection joints and fittings for 
leaks with a non-corrosive leak detection fluid, 
then wipe off.
Gas suppliers recommend you purchase and 
install a UL approved gas detector. Install 
and use in accordance with the installation 
instructions.
WARNING
 
Do not use a flame to check for gas leaks.
 
Isolate the range from the gas supply system 
by closing its individual shut-off valve during 
any pressure testing of the gas supply system 
at test pressures equal to or less than 
1
/
2
" psig 
(3.5 kPa).
Flexible Connector Hookup
1
/
2
Adapter
Pressure regulator
Flex connector
(6 ft. max.)
Adapter
Gas shut-off 
valve
1
/
2
" or 
3
/
4
" Gas 
pipe
Gas Flow into Range
Installer: Inform the consumer of the location of the gas 
shutoff valve
.
Pressure Regulator Position 
Pressure Regulator