Jenn-Air 720-0100-NG User Manual

Page of 27
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
If the flames have yellow tips, loosen the locking 
nut and move the bolt in a clockwise direction.   
If the flames are making excessive noise or lifting, 
loosen the locking nut and turn the bolt in a counter-
clockwise direction.   
 
Remember to tighten the locking nut before 
relighting the burner.  If you have any questions 
regarding flame stability, please contact customer 
service at 1-800-554-5799. 
 
 
 
 
 
 
 
 
 
1. 
Specified clearance maintained 24in. from 
combustible materials/construction. 
 
2. 
All internal packaging has been removed. 
 
3. 
The hose and regulator are properly 
connected. 
 
 
 WARNING 
Burner adjustments should only be performed 
after the burners have cooled.   
 
Always tighten the locking nut before relighting 
the burner.  
INSTALLER FINAL CHECK
 
4. 
The unit has been tested and is free of leaks. 
 
5. 
The gas supply shut off valve has been 
located.  
 
6. 
All burners are factory installed. 
 
 
 
 WARNING 
1.  The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas 
supply piping system during any pressure testing of that system at test pressure in excess of ½psi 
(3.5kpa). 
 
2.  2.   The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing 
its individual manual shutoff valve during any pressure testing of the gas supply piping system at test 
pressure equal to or less ½psi (3.5kpa)  
        
 
9