Dacor 100500 User Manual

Page of 20
Rough-In Dimensions
◊ 
The solid sofit or ceiling should be within 1” (25mm) above 
the refrigerator. If the solid sofit is higher than 1” (25mm) or 
one is not available, then the refrigerator must be braced to 
prevent tipping during use. If the anti-tip blocking is need. 
(see “Anti-Tip Blocking” on page 9)
NOTE:
 A clearance of 1/2” (13mm) must be maintained above 
the top grill in order for the top grill to be opened.
◊ 
A grounded 3 prong non-GFCI electrical outlet should be 
placed 2” (51mm) from the right side cabinets or end panel. 
See “Electrical Requirements” for additional information.
◊ 
The plumbing for the water line can come through the floor 
or the back wall. See “Water Supply Requirements” for more 
information.
i
nsTallaTion
 s
PeCifiCaTions
7”
4”
2”
6”
3”
75 1/2”
“A”
83 3/4”
Water Supply
Electrical
24”
e
leCTRiCal
 R
equiRemenTs
A 115VAC, 60 Hz, 15 Amp circuit breaker and electrical supply are 
required. A separate dedicated non-GFCI circuit, servicing only 
this appliance, is required.
Your Dacor
®
 Built-In refrigerator is equipped with a 40” (1016mm) 
3-prong grounded power cord, which must be plugged into a 
3-prong grounding-type non-GFCI wall receptacle. Follow the 
National Electrical Code and local codes and ordinances when 
installing the receptacle. See “Rough-In Dimensions” for location 
of the electrical supply.
IMPORTANT:
 A ground fault circuit interrupter (GFCI) is not 
recommended and may cause interruption of operation.
 WARNING
ELECTRICAL SHOCK HAzARD – Plug into a grounded 3-
prong non-GFCI outlet. Do not remove ground prong. Do not 
use an adapter. Do not us an extension cord. Failure to do so 
can result in death, fire, or electrical shock
.
◊ 
All installations must meet local plumbing code 
requirements.
◊ 
Connect to 1/4” (6mm) copper line to the house cold fresh 
water supply.
◊ 
Use a shut off valve between the refrigerator and supply. 
The shut off valve should be a drilled saddle valve.
◊ 
Do not use a self-tapping valve which reduces water flow 
and clogs more easily.
◊ 
Route the water line within 3-1/2” (89mm) of the rear wall 
and no higher than 3” (76mm) from the floor. 
◊ 
Allow a minimum of 24” (610mm) dimeter service loop of 
copper tubing outside the wall or floor for easy connection to 
the water supply.
Cold water supply
Connect the ice maker to a cold water line with water pressure 
between 30 and 120 PSI. If you have any questions about your 
water pressure, call your utility company.
IMPORTANT:
◊ 
In homes with a Reverse Osmosis water treatment system, 
remove the water inlet connector from the “yellow” valve 
and attached to the “blue” valve. Make sure the water filter 
bypass plug is in place.
w
aTeR
 s
uPPly
 R
equiRemenTs
Model
Rough-In Width “A”
42-Inch
41 1/2”” (1054mm)
48-Inch
47 1/2”” (1207mm)