Haier 232738 User Manual

Page of 30
Advanced Troubleshooting 
14
309477F
Building circuit breaker opens 
as soon as sprayer is plugged 
into outlet and sprayer is NOT 
turned on.
NOTE: Remove enclosure 
mounting screws and pull 
enclosure away from drive 
housing. Take care not to pull 
on leads from electrical cord 
and power switch.
Sprayer electrical cord is 
damaged
1. Unplug sprayer electrical cord. 
2. Disconnect black electrical cord wire at 
power switch
3. Unplug in-line connection white cord wire.
4. Plug in electrical cord
5. Test voltage between black and white 
wires. Meter must read 200-260 V AC.
6. Replace electrical cord if no voltage.
Sprayer power switch damaged
1. Unplug sprayer electrical cord.
2. Disconnect black control board wire at 
power switch.
3. Check resistance of switch with ohmmeter.
4. Reading must be infinity with power switch 
OFF.
5. Reading must be zero with power switch 
ON.
6. Replace power switch if damaged.
Also “Basic Electrical Problems” and “Sprayer Wiring Problems”, page 12.
Specific Problem
Cause
Solution
General Problem: Erratic Motor Operation
Specific Problem
Cause
Solution
Sprayer quits after running for 
5 to 10 minutes
Electrical outlet is damaged
Reset building circuit breaker or replace building 
fuse. 
Electrical outlet supplying 
wrong voltage
Try another outlet. Check electric supply with volt 
meter. Meter must read 200-260 V AC. If voltage 
is too high, do not use outlet until corrected.
Also “Basic Electrical Problems” and “Sprayer Wiring Problems”, page 12.
Motor is overheating
“Motor is Hot”, page 10.