CCU Trunk Communication Board (TCB4)
4.5.2 S9 DIP-Switch settings
for functionality of the DIP-switches.
4.5.3 Jumper settings
for location, and
for functionality of the jumpers.
Table 4-3: S9 DIP-switch settings
TCB4
SW 1
ON*
OFF
Chairman priority tone ON (default).
Chairman priority tone OFF
SW 2
ON
OFF*
Audio ‘Mix-Minus’ mode activated in combination with SW3 = OFF
Normal Operation (default).
SW 3
ON
OFF*
Audio ‘Insertion’ mode activated in combination with SW2 = OFF
Normal Operation (default).
SW 4
OFF*
ON
ON
Floor distribution ON (default).
No floor distribution on unused language channels
No floor distribution on unused language channels
SW 5
OFF
Reserved (IMPORTANT: must not be changed)
SW 6
ON
OFF*
Active microphones and request will be permanently switched off if
the priority function of the chairman unit is used. (default).
the priority function of the chairman unit is used. (default).
Active microphones will be switched off temporarily if the priority
function of the chairman unit is activated.
function of the chairman unit is activated.
SW 7
OFF
Reserved (IMPORTANT: must not be changed)
SW 8
ON
OFF*
Switching on the CCU will activate the BOOT software, this makes a
new download possible. All memory settings will be erased and
returns to the default settings. The unit addresses will not be erased.
new download possible. All memory settings will be erased and
returns to the default settings. The unit addresses will not be erased.
Normal operation (default).
* = default setting
DIP switch S9 (default settings)
For location
see
FIG. 4-3
and
FIG 4-5
.
S9
ON
1 2 3 4 5 6 7 8
switches 5 and 7 are ‘RESERVED’
Must NOT be changed
Must NOT be changed
Table 4-4: Jumper settings
Jumper
Default
Function
3
X13
1 & 2
Jumpered to provide SRAM Battery back-up
Open when removing back-up battery. (Position 2 & 3)
Open when removing back-up battery. (Position 2 & 3)
7
X14
1 & 2
Watchdog active
Open for service purposes. (Position 2 & 3)
Open for service purposes. (Position 2 & 3)