PROTECTION
destination register and sets the ZF flag in the EFLAGS register. If the segment 
selector is not visible at the current privilege level or is an invalid type for the LSL 
instruction, the instruction does not modify the destination register and clears 
the ZF flag.
Once loaded in the destination register, software can compare the segment limit with 
the offset of a pointer. 
5.10.4 
Checking Caller Access Privileges (ARPL Instruction)
The requestor’s privilege level (RPL) field of a segment selector is intended to carry 
the privilege level of a calling procedure (the calling procedure’s CPL) to a called 
procedure. The called procedure then uses the RPL to determine if access to a 
segment is allowed. The RPL is said to “weaken” the privilege level of the called 
procedure to that of the RPL. 
Operating-system procedures typically use the RPL to prevent less privileged appli-
cation programs from accessing data located in more privileged segments. When an 
operating-system procedure (the called procedure) receives a segment selector from 
an application program (the calling procedure), it sets the segment selector’s RPL to 
the privilege level of the calling procedure. Then, when the operating system uses 
the segment selector to access its associated segment, the processor performs priv-
ilege checks using the calling procedure’s privilege level (stored in the RPL) rather 
than the numerically lower privilege level (the CPL) of the operating-system proce-
dure. The RPL thus insures that the operating system does not access a segment on 
behalf of an application program unless that program itself has access to the 
segment.
Figure 5-15 shows an example of how the processor uses the RPL field. In this 
example, an application program (located in code segment A) possesses a segment 
selector (segment selector D1) that points to a privileged data structure (that is, a 
data structure located in a data segment D at privilege level 0). 
The application program cannot access data segment D, because it does not have 
sufficient privilege, but the operating system (located in code segment C) can. So, in 
an attempt to access data segment D, the application program executes a call to the 
operating system and passes segment selector D1 to the operating system as a 
parameter on the stack. Before passing the segment selector, the (well behaved) 
application program sets the RPL of the segment selector to its current privilege level 
(which in this example is 3). If the operating system attempts to access data 
segment D using segment selector D1, the processor compares the CPL (which is 
now 0 following the call), the RPL of segment selector D1, and the DPL of data 
segment D (which is 0). Since the RPL is greater than the DPL, access to data 
segment D is denied. The processor’s protection mechanism thus protects data 
segment D from access by the operating system, because application program’s priv-
ilege level (represented by the RPL of segment selector B) is greater than the DPL of 
data segment D.