HP (Hewlett-Packard) ML110 G6 User Manual

Page of 115
 
 
Diagnostics tools  99  
 
 
POST related troubleshooting  
Perform the following procedures when POST fails to run, displays error messages, or emits beep 
codes. 
If the POST failure is during a routine boot up, check the following: 
 
All external cables and power cables should be firmly plugged in. 
 
The power outlet to which the server is connected and is working. 
 
The server and monitor are both turned on. The bicolor status LED indicator on the front panel 
must be lit up green. 
 
The monitor's contrast and brightness settings are correct. 
 
All internal cables are properly connected and all boards are firmly seated. 
 
The processor is fully seated in its socket on the system board. 
 
The heat sink is properly installed on top of the processor. 
 
All memory modules are properly installed. 
 
If you have installed a PCI expansion board, verify that the board is firmly seated and any 
switches or jumpers on the board are properly set. Refer to the documentation provided with the 
expansion board. 
 
All system cables are securely connected and are in their proper order. 
 
If you have changed any switches on the system board, verify that each is properly set.