Schneider Electric 17S Series User Manual

Page of 146
76
Warning Messages
Warning 
Identification 
and Description
A warning is generated when a non-fatal fault occurs. Non-fatal faults allow the 
drive to remain enabled and the fault relay contact to remain closed.   Either of the 
programmable digital outputs can be programmed to indicate that a warning 
condition has been detected. The cause of the warning is presented as an 
alphanumeric code on the drive’s front panel LED display; these warning codes are 
identified and described in the following table.
Warning 
Code
Designation
Explanation
n01
I²t warning
Current threshold set by “I²t Message” parameter 
was exceeded.
n02
Regen power
Power threshold set by “Max Regen Power” 
parameter was exceeded.
n03
Following Fault
Following error threshold set by “Following Error” 
parameter was exceeded.
n04
Response monitoring
Response monitoring (fieldbus)is active.
n05
Mains phase
Mains phase missing. Can be disabled for single 
phase operation with the “Mains Phase Missing” 
parameter.
n06
Sw limit-switch 1
Passed software limit-switch 1.
n07
Sw limit-switch 2
Passed software limit-switch 2.
n08
Motion task error
A faulty motion task was started.
n09
No “Home” reference point
Motion task started with no “Home” reference 
point set.
n10
Positive Limit
Positive limit-switch activated.
n11
Negative Limit
Negative limit-switch activated.
n12
Default values
Only HIPERFACE®: motor default values loaded.
n13
SERCOS interface
SERCOS interface not functioning correctly.
n14
HIPERFACE®-reference 
mode 
Attempt to reset while HIPERFACE®-reference 
mode was active.
n15
Table error
Velocity current table INXMODE 35 error
n16 ... n31 Reserved
reserved
n32
Firmware beta version
The firmware is not a released beta version
A
Reset
RESET is active at DIGITAL IN x