Fault Relay and Digital I/O Connection, continued
Using Functions 
Pre-programmed 
into the Drive
Fault Relay- The isolated fault relay contacts are closed during normal operation 
and open when a fault condition exists. The relay state is not affected by the enable 
signal, I
2
t limit or warnings. All faults cause the Fault RA/RB contact to open and 
the switch-off of the output stage. A list of error messages can be found in chapter 
Troubleshooting.
Digital Inputs 1, 2, 3 and 4 - You can use the four digital inputs to initiate pre- 
programmed functions that are stored in the drive.
Digital Outputs 1 and 2 - You can use the two digital outputs to send messages 
from pre-programmed functions that are stored in the drive.
Enable Input - This is a dedicated, level-sensitive (as opposed to edge-sensitive) 
hardware input which will enable the output stage of the drive when 24 Vdc is 
applied and no fault conditions exist.
Note: The hardware enable is powered up upon detection of state sense versus 
transition sensitivity. Refer to the UniLink on-line help for software enable 
information.