Schneider Electric 17S Series User Manual

Page of 146
90
Electrical Specifications - Power, continued
Motor Output 
Specifications 
Table
The following table provides 17S motor output specifications.
Note: Motors must be compatible with following table:
Continued on next page
Parameter
Type
Model Number
Current
Output current (RMS)
Continuous
MHDS1004N00*
1.5 A
MHDS1008N00
3 A
MHDS1017N00
6 A
MHDS1028N00
10 A
MHDS1056N00
20 A
Intermittent**
MHDS1004N00
3 A
MHDS1008N00
6 A
MHDS1017N00
12 A
MHDS1028N00
20 A
MHDS1056N00
40 A
Switching frequency
8 kHz ± 0.1%
Cable length***
75 m (maximum)
Maximum cable capacitance (motor 
phase to ground or shield)
150 pF/m
* For single phase main connection, the output current is limited to the output
current specifed above or 4 amps, whichever is lower.
** Duration depends on settings in Unilink.
*** Cable lengths exceeding 25 m require the use of motor choke AM0FIL001V056
Motor Inductance:
Model
Min (mH)
Max (mH)
MHDS1004N00
16
400
MHDS1008N00
8
200
MHDS1017N00
4
100
MHDS1028N00
3.5
60
MHDS1056N00
1.5
30