4.3.2
Failed Devices
The audible alarm will be triggered if any of the following devices fail:
•
Cooling fan modules
•
PSU modules
•
BBU modules
•
Hard drives
•
Components on the RAID controller
4.4
I
2
C Monitoring
Module presence detection and the general working status of cooling fan and other modules
are monitored through an I
2
C serial bus. If any of these modules fails, the failure will be
detected and you will be notified via the various methods described above.
i
NOTICE!
If the temperature exceeds a preset threshold, the BBU charger circuits will stop charging.
You will then receive a message that says “Thermal Shutdown/Enter Sleep Mode.” When the
temperature falls back within normal range, the battery will resume charging.