Siemens LR 460 User Manual

Page of 123
7ML19985JM01
SITRANS LR 460 – INSTRUCTION MANUAL 
Page 17
mmmmm
In
st
a
lla
ti
o
n
Universal Slotted Flange (for use with Air Purging Option 
only)
Slotted Flange Dimensions (see above)
WARNING: The user is responsible for the selection of bolting and 
gasket materials which will fall within the limits of the flange and its 
intended use and which are suitable for the service conditions.
Pipe 
Size
Flange 
O.D.
Thick-
ness (s)
Bolt Hole 
Circle Max Ø
Bolt Hole 
Circle Min Ø
Bolt Hole 
radius
No. of 
Slotted 
Holes
3" or 
80 mm
7.87"
(200 mm)
0.38" 
(9.65 mm)
6.30" 
(160 mm)
5.91" 
(150 mm)
0.38" 
(9.5 mm)
8
4" or 
100 mm
9.00"
(229 mm)
0.38" 
(9.65 mm)
7.52" 
(191 mm)
6.89" 
(175 mm)
0.38" 
(9.5 mm)
8
6" or 
150 mm 
11.22"
(285 mm)
0.38" 
(9.65 mm)
9.53" 
(242 mm)
9.45" 
(240 mm)
0.45" 
(11.5 mm)
8
flange O.D.
bolt hole circle 
min. diameter
number of slotted bolt holes
section A-A
thickness
bolt hole circle max. diameter