Siemens LR 460 User Manual

Page of 123
7ML19985JM01
SITRANS LR 460 – INSTRUCTION MANUAL 
Page 13
mmmmm
In
st
a
lla
ti
o
n
Key considerations
Correct location is critical to a successful application. 
Avoid reflective interference from vessel walls and obstructions by following the 
guidelines below.
Nozzle design
Bottom edge of horn must project 
from nozzle.
Nozzle must allow adequate 
clearance to allow positioning if LR 
460 has to be at an angle so that 
emission cone perpendicular to 
material surface. 
Nozzle location
Locate antenna at least 1 meter away 
from side wall.
Keep emission cone free of interference 
from ladders, pipes, I-beams or filling 
streams. 
Make allowance for beam spread to 
avoid interference with the emission 
cone. 
Device orientation
Align the antenna so that the radar 
cone is perpendicular to the surface 
of the monitored material, if possible. 
(See 
15.)
To compensate for vessels with 
obstructions, see also 
Min. clearance: 
10 mm (0.4") 
SITRAN
S LR 40
0
SITRAN
S LR 40
0
min. 1 m (39")
emission 
cone
4" horn
3" 
horn
11°