Siemens LR 460 User Manual

Page of 123
7ML19985JM01
SITRANS LR 460 – INSTRUCTION MANUAL 
Page 9
mmmmm
S
p
ec
if
ic
at
io
n
s
Enclosure
• construction
Die-cast aluminum, painted (polyester powder-coated)
• conduit
2 x M20 
or 2 x ½” NPT (option)
• ingress protection
Type 4X/NEMA 4X, Type 6/NEMA 6, IP67
1
Dust cap (optional)
• 3"
PTFE, pipe clamp connection, O.D. 95 mm (3.74")
• 4"
PTFE, pipe clamp connection, O.D. 120 mm (4.72")
Air Purge Connection
• equipped with female 1/8" NPT fitting
Environmental
• location
indoor/outdoor
• altitude
2000 m (6562 ft) max
• relative humidity
suitable for outdoor (Type / NEMA 4X, 6/ IP67)
• installation category
II
• pollution degree
4
• permitted ambient
-40 to 65 °C (-40 to 149 °F) (non-hazardous version)
temperature
3
LCD: -10 to 55 °C (14 to 131 °F)
Observe the temperature classes in hazardous areas!
Process
• Process temperature
2
-40 to 200 °C (-40 to 392 °F)
• Pressure (vessel) 
0.5 bar (7.25 psi) maximum
Communication
Communication: HART
• Load
230 to 600 
Ω, 230 to 500 Ω when connecting a coupling
module
• Max. Line Length
multi-wire: 
≤ 1500 m (4921 ft)
• Protocol
HART, Version 5.1
1.
Use only approved, suitable sized hubs for watertight applications.
2.
Process temperature varies with ambient temperature. See Process/Ambient de-rating curves in 
Appendix III.