Specifications
SITRANS LR 460
Power
Power Supply 
• 100 to 230 V AC, 
±
15%, 50/60 Hz, 6 W 
• 24 V DC, +25/-20%, 6 W
• Fuse (AC)
SI1
Fast acting ceramic, 4 x 20 mm, 1 A, 250 V AC
SI2
Slow-Blow, 4 x 20 mm, 0.63 A, 250 V AC
• Fuse (DC)
SI1
Fast acting ceramic, 4 x 20 mm, 2 A, 250 V AC
SI2
Slow-Blow, 4 x 20 mm, 0.63 A, 250 V AC
Performance
Reference operating conditions according to IEC 60770-1
• ambient temperature
+15 to +25 
o
C
• humidity 
45 to 75% relative humidity
• ambient pressure
860 to 1060 mbar (12.47 to 15.37 psi)
Measurement Accuracy (measured in accordance with IEC 60770-1)
• non-linearity (accuracy)
greater of 25 mm (1”) or 0.25% of span (including 
hysteresis and non-repeatability)
• non-repeatability
10 mm (0.4”) [included in non-linearity specification]
• deadband (resolution)
10 mm (0.4”) [included in non-linearity specification]
• hysteresis error
0 mm
Analog Output Accuracy (measured in accordance with IEC 60770-1)
• non-linearity (accuracy)
0.100% of span (including hysteresis and repeatability)
• non-repeatability
0.030% of span (included in non-linearity specification)
• deadband (resolution)
0.030% of span [included in non-linearity specification]
• hysteresis error
0%
Frequency
25 GHz nominal
Measurement range
1
0.35 to 100 m (1.15 to 328.08 ft). 
Note: 
Siemens Milltronics makes every attempt to ensure the accuracy of these 
specifications, but reserves the right to change them at any time. 
1.
Referenced from flange face.